KSN-2 – Two-Pump Control Panel

KSN-2 is an electronic control panel configured to monitor, protect and operate two pumps in manual or automatic mode. It controls clean-water and wastewater applications using pressure or level signals.

Request a Quote
KSN-2 – Two-Pump Control Panel

Product Overview

KSN-2 is an electronic control panel configured to monitor, protect and operate two pumps in manual or automatic mode. It controls clean-water and wastewater applications using pressure or level signals.

Key Features

Integrated current measurement

Current and voltage values are monitored together through the LCD interface.

High-precision overcurrent protection

Current, phase, thermistor and field-sensor signals are evaluated by the protection logic.

Pressure control

Pressure and level inputs support manual or automatic pump control.

Voltage-free contacts

Fault and status information is provided audibly, visually and through voltage-free contacts.

Technical Specifications

Motor Power Range0.37–7.5 kW per pump

Electrical Monitoring

  • Integrated current measurement
  • Integrated voltage measurement

Protection Functions

  • High-precision overcurrent protection
  • High-precision undercurrent and dry-run protection
  • Voltage fluctuation protection
  • Mechanical-seal leakage monitoring
  • Thermistor protection
  • Phase sequence and phase failure protection
  • Overflow level warning
  • Limited automatic fault reset

Pump Control

  • Automatic pump recognition
  • Configurable switching / start limit
  • Pressure control
  • Tank level control
  • Manual and automatic operation

Inputs & Outputs

  • Fault output for automation
  • Mechanical-seal leakage monitoring
  • Voltage-free contacts

User Interface

  • LCD display and setup keys
  • Audible alarm and visual fault indication

Protection Functions

High-precision overcurrent protection
High-precision undercurrent and dry-run protection
Voltage fluctuation protection
Mechanical-seal leakage monitoring
Thermistor protection
Phase sequence and phase failure protection
Overflow level warning
Limited automatic fault reset

Starting Options

The starting method is selected as part of the panel configuration after evaluating the motor and project requirements.

Starting

Direct On Line (DOL)

The starting method is selected as part of the panel configuration after evaluating the motor and project requirements.

Starting

Soft Starter

The starting method is selected as part of the panel configuration after evaluating the motor and project requirements.

Starting

Variable Frequency Drive (VFD)

The starting method is selected as part of the panel configuration after evaluating the motor and project requirements.

Applications

Application

Booster systems

Application

Clean-water supply

Application

Drainage systems

Application

Wastewater transfer

Application

Agricultural irrigation

Application

Building applications

Application

Energy and infrastructure applications

Documents

No downloadable document is currently published for this product. Contact our team to request technical documentation.

Contact

Product Gallery

KSN-2 – Two-Pump Control Panel

Request a Quote for Your Project

Share the pump count, application details and any available technical drawing so our team can evaluate the appropriate panel configuration.

Request a Quote

Keskin Enerji

WhatsApp: Send Message
Address: Çatalmeşe Mah. 225. Sok. No: 6/2 Çekmeköy / İstanbul